Federal University Oye-Ekiti Institutional Repository >
FACULTY OF ENGINEERING >
Mechanical Engineering >
Mechanical Journal Publications >

Please use this identifier to cite or link to this item: http://repository.fuoye.edu.ng/handle/123456789/1272

Title: Theoretical Comparison of Two of Eco-Friendly Refrigerants as Alternative to R22 in using a Simple Vapour Compression Refrigeration System
Authors: Bolaji, Bukola Olalekan
Abiala, I.O.
Ismaila, S.O.
Borokinni, F.O.
Keywords: eco-friendly
alternative refrigerants
performance
R432A, R433A
Issue Date: 2014
Publisher: Transactions of Famena, Published by the Faculty of Mechanical Engineering and Nava Architecture, University of Zagreb, Croatia.
Series/Report no.: Volume 38;No. 3, pp. 59-70
Abstract: Theis paper presents a theoretical investigation of into the performance of R432A and R433A refrigerants as alternatives to the ozone depleting R22 refrigerant. The two refrigerants have zero ozone depleting potential and a negligible global warming potential. The results obtained showed that the properties of the three investigated refrigerants are similar. The saturation vapour pressures for R432A and R433A, between the saturation temperatures of -30 to 40oC, are 99.6 and 99.3% the same with as that of R22. The performance of R22 in terms of power per ton of refrigeration (PPTR), vVolumetric Rrefrigeration cCapacity (VRC) and Ccoefficient of pPerformance (COP) is slightly better better higher than those the performance of the two alternative refrigerants. The average COPs obtained for R432A and R433A were slightly lower by only 4.5 and 5.4%, respectively, than those of R22, respectively, but the two alternative refrigerants equally exhibited better pressure ratios, discharge temperatures and pressures than R22. Both R432A and R433A have higher refrigerating effects than R22. The VRC and COP of R432A are higher by 3.8% and 0.9%, respectively, than those of R433A, respectively. Generally, the performance of the two alternative refrigerants is quite similar in all the operation conditions and they have shown satisfactory performance as good long term alternatives to R22 refrigeration systems.
URI: http://repository.fuoye.edu.ng/handle/123456789/1272
Appears in Collections:Mechanical Journal Publications

Files in This Item:

File Description SizeFormat
75-2014 Famena Performance of Eco-Friendly R432A & R433A as R22 Alternatives 38(3)59-70.pdf383.31 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback