Federal University Oye-Ekiti Institutional Repository >
FACULTY OF ENGINEERING >
Metallurgical and Material Engineering >
Metallurgical and Material Engineering Journal Publications >

Please use this identifier to cite or link to this item: http://repository.fuoye.edu.ng/handle/123456789/150

Title: Numerical Model on Frost Height of Round Plate Fin Used for Outdoor Heat Exchanger of Mobile Electric Heat Pumps
Authors: Moo-Yeon Lee
Keywords: Frost
Height
Round plate fin
Growth
Issue Date: 2012
Citation: Yan, W. M.; Li, H. Y.; Wu, Y. J.; Lin, J. Y.; Chang, W. R.; Performance of finned tube heat exchangers operating under frosting conditions. Int. J. Heat Mass Transfer, 2003, 46, 871-877.
Abstract: The objective of this study is to provide the numerical model for prediction of the frost growth of the round plate fin for the purpose of using as a round plate fin- tube heat exchanger (evaporator) under frosting conditions. In this study, numerical model was considering the frost density change with time, and it showed better agreement with experimental data of Sahin (1994) than that of the Kim model (2004) and the Jonse and Parker model (1975). This is because the prediction on the frost height with time was improved by using the frost thermal conductivity reflecting the void fraction and density of ice crystal with frost growth. Therefore, the developed numerical model could be used for frosting performance prediction of the round plate fin-tube heat exchanger.
Description: The objective of this study is to provide the numerical model for prediction of the frost growth of the round plate fin for the purpose of using as a round plate fin- tube heat exchanger (evaporator) under frosting conditions. In this study, numerical model was considering the frost density change with time, and it showed better agreement with experimental data of Sahin (1994) than that of the Kim model (2004) and the Jonse and Parker model (1975). This is because the prediction on the frost height with time was improved by using the frost thermal conductivity reflecting the void fraction and density of ice crystal with frost growth. Therefore, the developed numerical model could be used for frosting performance prediction of the round plate fin-tube heat exchanger.
URI: http://repository.fuoye.edu.ng/handle/123456789/150
Appears in Collections:Metallurgical and Material Engineering Journal Publications

Files in This Item:

File Description SizeFormat
Numerical Model on Frost Height of Round Plate Fin Used for Outdoor Heat Exchanger of Mobile Electric Heat Pumps .pdf339.29 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback